Automated measurement turns statistical process control (SPC) from a sampling exercise into continuous monitoring. When a vision system or data acquisition system measures every part, its results can feed control charts directly, so drift is visible within minutes instead of at the next manual sample. The data is only useful if the measurement system is capable and the charts are set up for the volume.

This article is part of our data acquisition guide. It is written for quality and continuous improvement engineers connecting automated measurements to SPC.

In short

  • Prove the measurement system first: gage R&R before control charts.
  • 100% measurement needs subgrouping, or the charts alarm on noise.
  • Charts should watch the process, not just pass or fail parts.
  • Store measured values with time, part and lot, or you can’t trace a shift.

What changes when every part is measured

Manual SPCAutomated measurement
DataA few parts per hour, recorded by handEvery part, recorded automatically
Detection of a shiftAt the next sample, sometimes hours laterWithin a few subgroups
Typical errorsTranscription, rounding, skipped samplesMeasurement system drift, if not verified
EffortInspector time for every sampleSet-up and periodic verification

Setting up control charts for high-volume data

  • Subgroup the data. Charting every individual value on a fast line produces constant alarms from normal variation. Group consecutive parts, for example 5 at a time, and chart the subgroup mean and range.
  • Base limits on stable data. Calculate control limits from a period when the process was running normally, not from specification limits.
  • Watch the right characteristic. Chart the dimensions or signals that predict defects, not just the reject count.
  • Use run rules carefully. With thousands of points a day, every extra rule adds false alarms. Start with points outside the limits and runs on one side of the center line.

Capability from automated data

Process capability compares the spread of the process with the specification. For a dimension with limits of 9.95 to 10.05 mm, a mean of 10.02 mm and a standard deviation of 0.01 mm:

  • Distance to the upper limit: (10.05 − 10.02) ÷ (3 × 0.01) = 1.00
  • Distance to the lower limit: (10.02 − 9.95) ÷ (3 × 0.01) = 2.33
  • Cpk = 1.00, the smaller of the two

The process is capable on spread but sits off-center toward the upper limit. Re-centering, not tighter control, is the fix. Automated data makes this visible quickly because the sample is large.

Make sure the measurement can be trusted

If the measurement system contributes much of the variation, the control chart shows the gauge, not the process. Before using automated data for SPC:

  • Run a gage R&R study on the measurement.
  • Know the measurement uncertainty compared with the tolerance.
  • Check a reference part each shift and chart it separately, so measurement drift isn’t mistaken for process drift.

Data you need to store

For each measurement: the value, timestamp, part or serial number, lot, station, recipe and software version. This lets you trace a shift to a material lot, a tool change or a station, and it is what auditors and customers ask for.

Want SPC from your automated measurements?

Sciotex builds data acquisition, vision and test systems that measure every part and store traceable results ready for SPC, on any hardware and language. Designed, programmed, built and supported in the US since 1997.

Explore our DAQ systems

Frequently asked questions

Can automated measurement data be used for SPC?

Yes. Results from vision, test or data acquisition systems can feed control charts directly, as long as the measurement system is capable and the data is subgrouped for the volume.

Why does 100% measurement cause too many SPC alarms?

Charting every individual value on a fast line exposes normal variation and makes run rules trigger often. Subgrouping consecutive parts and limiting run rules reduces false alarms.

Should control limits be based on specification limits?

No. Control limits come from the process’s own stable variation; specification limits define what the customer will accept.

How do I know if my measurement system is good enough for SPC?

Run a gage R&R study and compare measurement uncertainty with the tolerance. If the measurement system contributes much of the variation, the charts mostly show the gauge.

What data should be stored for automated SPC?

The measured value, timestamp, part or serial number, lot, station, recipe and software version, so a shift can be traced to its cause.

Related articles

Written by

Sciotex Engineering

The Sciotex engineering team has designed and built vision, automation and test systems since 1997.

Have an inspection problem to solve?

Talk it through with a Sciotex engineer.

In this article
Planning a DAQ project?

Talk it through with a Sciotex engineer.

Next step

Need a DAQ system that just works?